Sensorless Vector Control (SVC), V/F Control, and Torque Control. Starting Torque: 150% at 0.5Hz (SVC mode). Speed Regulation Ratio: 1:100 (SVC). 2. Mechanical Installation Guidelines
Programmable multi-function digital inputs (e.g., multi-speed step, fault reset, jog).
| Error Code | Name | Likely Cause (Per Manual) | Solution | | :--- | :--- | :--- | :--- | | | Overcurrent at acceleration | Short circuit, wrong motor parameters, or too fast ramp | Increase acceleration time (F2.00). Check motor insulation. | | Err.OC2 | Overcurrent at deceleration | Braking resistor missing, regenerative overvoltage | Add braking resistor or increase decel time (F2.01). | | Err.OC3 | Overcurrent at constant speed | Load shock, mechanical jam | Reduce load or check gearbox. Enable torque limit (F7.xx). | | Err.Ou1 | Overvoltage | Inverter braking too much energy | Increase decel time or install braking unit. | | Err.Ou2 | Undervoltage | Input power sag, missing phase on R,S,T | Check incoming supply voltage and wiring. | | Err.OH | Overheat | Fan failure, ambient too high ( >40°C) | Clean heatsink, replace fan. Reduce carrier frequency (F0.19). | | Err.SC | Short circuit | Motor wiring short to ground | Use a megger to test motor and cable. | Convo Inverter Cvf G3 Manual
| Specification | Details | | :--- | :--- | | | CVF-G3 (General Purpose) / CVF-P3 (Fan & Pump) | | Power Range | 0.75 kW to 450 kW | | Input Voltage | Three-phase 380VAC 50/60Hz (Allowable range: 320V~460V) | | Output Voltage | 0~380VAC | | Output Frequency | 0 Hz ~ 500 Hz | | Overload Capacity | G3 Series: 150% for 1 minute, 180% for 2 seconds | | | P3 Series: 120% for 1 minute, 150% for 2 seconds | | Control Method | V/F Control or Sensorless Vector Control (depending on model) | | Protection Level | IP20 (Typical, for indoor installation) | | Communication | Standard RS485 interface | | Mounting Type | Wall-mounted or cabinet type |
What are you trying to run?
The red emergency light bathed the maintenance bay in the color of blood. Elias wiped grease from his forehead with the back of a trembling hand, leaving a dark smear.
| Parameter | Value | Explanation (from manual) | | :--- | :--- | :--- | | | 0 | 0 = Keypad command (Run/Stop from inverter keys) | | F0.01 | 0 | 0 = Keypad potentiometer for frequency setting | | F1.01 | 380V (or 220V) | Motor rated voltage (from motor nameplate) | | F1.02 | 5.0A | Motor rated current (critical for overload protection) | | F1.03 | 1420 RPM | Motor rated speed | | F2.00 | 5.0 sec | Acceleration time from 0Hz to 50Hz | | F2.01 | 5.0 sec | Deceleration time (increase if overvoltage trips) | Sensorless Vector Control (SVC), V/F Control, and Torque
The CVF-G3 series utilizes advanced sensorless vector control technology. It delivers high torque at low speeds, high speed accuracy, and robust reliability for industrial automation. Key Specifications V/F control, Sensorless Vector Control (SVC). Starting Torque: 150% at 0.5Hz (SVC). Speed Adjustment Range: 1:100 (SVC).
: Acceleration ramp profile is too aggressive, the driven load is jammed, or there is an insulation breakdown in the motor windings. Check motor insulation